Adsorption Applications of Electronic Specialty Gases

Download PDF

1. Introduction

Electronic specialty gases are essential foundational materials in modern electronics manufacturing—often referred to as the "blood" or "food" of the industry. These high-purity gases are critical to the production of semiconductors, display panels, LEDs, and photovoltaics. In 2021, the demand from these sectors accounted for 43%, 21%, 13%, and 6% of total consumption, respectively [1].

The purity requirements for electronic specialty gases are stringent, typically at the 5N (99.999%) level, with some applications demanding 6N (99.9999%) or even higher. Gas purity and quality directly influence device yield and performance, making both synthesis and purification technologies central to specialty gas production. Common synthesis methods include electrolysis, chemical reactions, and combined electrochemical approaches, while purification techniques span adsorption, distillation, absorption, and membrane separation [1].

Semiconductor manufacturing, comprising thousands of highly specialized steps, relies on over 100 types of specialty gases—44 of which are commonly used. These include compounds such as trifluorine nitride, tetrafluorocarbon, and sulfur hexafluoride, typically supplied in liquid or pressurized gas form.

Each major semiconductor process uses specialty gases for critical roles:

  • Cleaning: Removes contaminants from wafers and surfaces using gases such as SF₆ and CF₄.
  • Coating (CVD/ALD): Deposits films through gas-phase reactions using precursors like tungsten hexafluoride, silane, ammonia, and nitrous oxide.
  • Lithography: Involves plasma formation from mixed gases (e.g., Ar/F/Ne, Kr/Ne) to generate stable, high-precision light sources for photomask patterning.
  • Etching: Selectively removes material using fluorocarbons such as CH₃F, CH₂F₂, CF₃H, and halogen gases like Cl₂ and HBr to define intricate microstructures.
  • Doping: Introduces conductivity to semiconductors using gases like arsine, phosphine, diborane, and trifluoroborane [2].

These processes demand precise control and validation of gas delivery, purity, and usage conditions—making gas analysis, gravimetric sorption, and breakthrough testing indispensable tools in quality assurance and process development.

The adsorption method leverages the principle that porous materials exhibit selective gas uptake depending on the molecular properties of the gas and the characteristics of the material. For a given porous adsorbent, different gases exhibit different adsorption capacities. When a gas mixture is passed through an adsorbent bed, gases with stronger affinities to the surface will be preferentially adsorbed, while those with weaker interactions will exit the system—achieving a separation effect. The adsorbed gas can subsequently be desorbed by thermal regeneration or gas purging, allowing for recovery of purified components [1].

One prominent application of this technique is the separation of xenon (Xe) and krypton (Kr)—a challenging and high-value target for gas purification. Xe and Kr are critical to industries such as semiconductors, medical imaging, aerospace, and lighting.

Wang et al. developed a negatively charged coordination ultramicroporous material, NbOFFIVE-2-Cu-i (ZU-62), that demonstrated a breakthrough in Xe/Kr separation performance [3]. ZU-62 features a finely tunable pore size and flexible framework, resulting in a unique inverse size sieving effect—a rare case where the larger atom (Xe) is selectively adsorbed over the smaller atom (Kr). As shown in FIGURE 1, static adsorption isotherms confirm high Xe uptake and preferential exclusion of Kr due to the material’s precise pore chemistry and geometry.

To validate the material's real-world separation efficiency, dynamic breakthrough experiments were performed at 273 K (FIGURE 2). Kr eluted early, while Xe showed delayed breakthrough—demonstrating strong selective adsorption of Xe. The system achieved production of >99.9% pure krypton from the effluent stream and record Xe capture of 206 mL/g (2.88 mmol/g), aligning well with isotherm data and confirming the industrial relevance of the material [3].

Figure 1 Adsorption and desorption isotherms of pure components of Xe and Kr by ZU-62 at 273 K and 298 K

Figure 2 (A) Pore penetration experiment of Xe/Kr (20/80) mixture at 273 K and 1 bar conditions; (B) Desorption signals of Xe and Kr during regeneration process at 298 K with a flow rate of 3.5 mL/min-1 of N2, the green curve represents the real-time cumulative purity of Xe.

2. Experiment

Sample Selection and Objective

Two metal-organic framework (MOF) materials were selected for adsorption and gas separation studies:

  • MOF-1: Targeted for SF₆/N₂ adsorption and separation
  • MOF-2: Targeted for Xe/Kr adsorption and separation

Both dynamic breakthrough experiments and static isotherm measurements were performed to evaluate the adsorption capacity and selectivity of each material under relevant conditions.

Dynamic Breakthrough Testing

Competitive adsorption experiments were performed using the BTSorb-100 Breakthrough Curve and Mass Transfer Analyzer from AMI. A 1 mL stainless steel adsorption column (inner diameter: 0.45 cm; bed height: 5 cm) was used for all tests.

  • SF₆/N₂ separation (MOF-1):
  • Temperature: 298 K
  • Pressure: 2 bar
  • Total flow: 30 mL/min
    • Composition: 13.5 mL/min N₂, 1.5 mL/min SF₆, 15 mL/min He (carrier)
  • Xe/Kr separation (MOF-2):
  • Temperature: 25°C
  • Pressure: 1 bar
  • Total flow: 3 mL/min
    • Composition: 0.6 mL/min Xe, 2.4 mL/min Kr

Breakthrough curves were recorded and used to assess gas retention times, separation resolution, and dynamic capacity for each system.

Static Adsorption Testing

Static adsorption isotherms were measured using the AMI Sync 400 Surface Area and Pore Size Analyzer. For both MOFs:

  • Sample mass: 0.12 g
  • Pretreatment: Vacuum degassing at 120°C for 12 hours
  • Measurement conditions:
  • SF₆/N₂ isotherms at 273 K (MOF-1)
  • Xe/Kr isotherms at 298 K (MOF-2)

The resulting data enabled comparison between static adsorption capacity and dynamic performance, offering insight into material structure-performance relationships.

3.Results and Discussion

Perfluorinated electronic specialty gases—including NF₃, CF₄, and SF₆—play a critical role in the fabrication of silicon-based semiconductors due to the strong chemical reactivity between fluorine and silicon. However, the conversion efficiency of F-gases in plasma processes is often below 60%, leaving unreacted F-gases and byproducts such as N₂, NOₓ, HF, and H₂O in the exhaust stream. As environmental regulations tighten and gas recovery becomes increasingly important, adsorbent-based purification has emerged as a key area of research and development.

To assess adsorption-based purification of SF₆, MOF-1 was tested for its separation capability in an SF₆/N₂ gas mixture.

 

Static Adsorption Behavior

As shown in FIGURE 3(a), static adsorption isotherms indicate that MOF-1 exhibits a significantly higher adsorption capacity for SF₆ compared to N₂. This disparity suggests the potential for selective adsorption and separation of SF₆ from nitrogen under controlled conditions.

Dynamic Breakthrough Performance

To evaluate real-world separation behavior, a dynamic breakthrough experiment was conducted using the BTSorb-100 system. A 10:90 SF₆/N₂ gas mixture was introduced at 298 K, 2 bar, and a total flow rate of 30 mL/min.

As shown in FIGURE 3(b), the breakthrough curve illustrates clear separation behavior:

  • N₂ began to elute at approximately 50 seconds
  • SF₆ broke through at around 250 seconds
  • The resulting separation window was approximately 200 seconds, representing the effective retention time of SF₆ on MOF-1 under these conditions

Calculated dynamic adsorption capacities were:

  • N₂: 0.905 mmol/g
  • SF₆: 0.857 mmol/g

These results were consistent with the static isotherm values, where MOF-1 adsorbed 1.01 mmol/g of N₂ at 95 kPa and 0.896 mmol/g of SF₆ at 9.28 kPa.

The close agreement between static and dynamic data confirms the reliability and practical relevance of the measured separation behavior. Taken together, these findings demonstrate that MOF-1 offers viable adsorption and separation performance for SF₆/N₂ systems, and highlights its potential use in semiconductor exhaust gas purification processes.

Figure 3 (a) Adsorption isotherms of SF6 and N2 on MOF-1 at 298K; (b) Competitive adsorption breakthrough curve of MOF-1 at a temperature of 298K, a total pressure of 2 bar, and a total flow rate of 30 mL/min (He/N2/SF6 = 50/45/5).

Xenon (Xe) and krypton (Kr) are high-value noble gases, often referred to as "golden gases" due to their scarcity and wide-ranging industrial applications. Their unique physical and chemical properties make them essential in fields such as semiconductor manufacturing, lighting, aerospace, medical imaging, and anesthesia [4]. As a result, the efficient separation and purification of Xe from Kr remains a high-priority challenge in specialty gas processing.

In this study, MOF-2 was evaluated for its ability to adsorb and separate Xe/Kr mixtures.

Static Adsorption Isotherms

As shown in FIGURE 4(a), adsorption isotherms measured at 273 K demonstrate that MOF-2 exhibits a significantly higher adsorption capacity for Xe compared to Kr. When the temperature was increased to 298 K (FIGURE 4(b)), the adsorption capacities of both gases decreased—consistent with exothermic physisorption behavior—but Xe remained more strongly adsorbed than Kr, suggesting favorable selectivity across a range of operating conditions.

These static results confirmed MOF-2’s potential for selective Xe adsorption from a Xe/Kr mixture.

Dynamic Breakthrough Testing

To evaluate separation performance under flow conditions, a competitive dynamic breakthrough experiment was conducted using a 20/80 (v/v) Xe/Kr binary gas mixture. The test was carried out at 298 K, 1 bar, and a total flow rate of 3 mL/min.

As shown in FIGURE 4(c):

  • Kr broke through the adsorption column in under 500 seconds
  • Xe did not appear in the effluent stream until ~2500 seconds
  • The breakthrough time difference exceeded 2000 seconds, indicating a long and effective separation window

Calculated adsorption capacities were:

  • Xe: 1.5489 mmol/g (dynamic), 1.6749 mmol/g (static at 20 kPa)
  • Kr: 0.9542 mmol/g (dynamic), 1.025 mmol/g (static at 80 kPa)

The close agreement between static and dynamic data, along with the large differential in breakthrough times, confirms that MOF-2 offers strong selectivity and capacity for Xe over Kr. These results demonstrate MOF-2’s practical utility for Xe purification from Kr-containing gas mixtures, with potential applicability in industrial gas recovery and semiconductor process optimization.

Figure 4 (a) Adsorption isotherms of Xe and Kr by MOF-4 at 273K; (b) Adsorption isotherms of Xe and Kr by MOF-4 at 298K; (c) Dynamic competitive adsorption curves of Xe/Kr by MOF-4 under normal temperature and pressure, total flow rate of 3 mL/min (Xe/Kr 20/80)

4. Conclusion

The results of this study confirm that advanced MOF materials offer strong potential for the selective adsorption and separation of high-value electronic specialty gases, including SF₆/N₂ and Xe/Kr mixtures. The close correlation between static isotherm data and dynamic

breakthrough results underscores the importance of combining both measurement approaches for accurate performance evaluation.

Using Sync 400 surface area and pore size analyzer and the BTSorb-100 breakthrough system, researchers were able to characterize adsorption behavior with high resolution and repeatability under realistic process conditions. These tools provided critical insights into both capacity and selectivity, enabling a comprehensive understanding of material performance.

As demand continues to grow for high-purity gases in semiconductor, medical, and aerospace industries, precision gas separation technologies will remain a key innovation area. AMI’s application-driven instrumentation supports the development and scale-up of advanced materials by delivering robust, accessible, and high-performance analytical solutions.

5. References

[1] He, H., Liu, Y., Zhang, J., et al. Research Progress in Synthesis and Purification Technologies of Electronic Specialty Gases. Low Temperature and Specialty Gases, 2023, 41(01): 1–5+46.

[2] China's Electronic Specialty Gases: From Import Substitution to Global Supply — In-depth Report on the Electronic Specialty Gas Industry.

[3] Wang, Q., Ke, T., Yang, L., Zhang, Z., Cui, X., Bao, Z., Ren, Q., Yang, Q., Xing, H. Angewandte Chemie, 2020, 132(9): 3451–3456.

[4] Zhao, Z. Research on Enhanced Xe/Kr Selective Adsorption Separation by Regulating Adsorbent Pore Environment. Nanchang University, 2023. DOI: 10.27232/d.cnki.gnchu.2023.003407.

 

DSC 600

INTRODUCTION

  • The DSC 600 from Advanced Measurement Instruments (AMI) is the next generation of Differential Scanning Calorimeters (DSC), crafted to meet the evolving needs of professionals in materials research, chemical engineering, quality control, petrochemicals, and pharmaceuticals. Designed for precision, reliability, and affordability, the DSC 600 sets new standards in thermal analysis.
  • At the heart of the DSC 600 is its innovative heat flux plate, engineered to capture the smallest energy changes with unmatched sensitivity and accuracy. This powerful capability enables precise measurements across a broad spectrum of applications, including enthalpy, glass transition, heat of crystallization, purity determination, and heat capacity.
  • Equipped with an ultra-light furnace, the DSC 600 ensures excellent thermal conductivity and stability, delivering consistent performance across a wide temperature range. With a selection of specialized heat flux plates, it can be tailored to meet diverse testing needs,enhancing efficiency and flexibility in every lab.
  • Typical Applications
  • Melting Temperature
  • Crystallization Temperature
  • Heat of Chemical Reaction
  • Glass Transition Temperature
  • Specific Heat Capacity
  • Degree of Crystallinity
  • Degree of Cure
  • Oxidative Stability
  • Thermal Stability
  • Solid-State Phase Transition
  • Liquid Crystal Phase Transition
  • Aging of Materials
  • Polymorph
  • DSC 600

FEATURES

  • Precision
  • High-sensitivity heat flow sensor platform delivers calorimetric accuracy of ±0.1%. With four distinct heat flow sensor types available, it comprehensively meets the precise measurement needs of diverse materials, accommodating a wide range of experimental and application scenarios.
  • Featuring innovative furnace technology and unique sensor design, the system achieves exceptional baseline repeatability while offering low noise, high sensitivity, and outstanding resolution. This ensures the detection of even minute thermal changes that might otherwise be lost in noise.
  • Stability
  • The mineral-insulated furnace body design combines excellent thermal conductivity with corrosion resistance, while dual-PID temperature control ensures data accuracy and stability.
  • Advanced circumferential heating technology and a proprietary dual-PID control system guarantee precise adherence to programmed temperature profiles during both heating and cooling phases. With temperature control accuracy of ±0.01°C, the system significantly minimizes thermal fluctuations that could compromise experimental results.
  • Ease of Use
  • The intuitive software interface features streamlined UI and modular architecture, enabling effortless operation. Researchers can quickly master experimental setup, data analysis, and all critical workflows.
  • The maintenance optimized furnace design allows easy cleaning even after sample contamination during loading, significantly enhancing experimental efficiency while extending equipment service life.
  • High-Precision Heat Flow Sensor
  • The self-developed high-sensitivity heat flow sensor platform delivers low noise, high sensitivity, and exceptional resolution to reliably detect minute thermal variations that might otherwise be obscured by noise.
  • Four Types of Heat Flow Sensors
  • The DSC600 offers four types of heat flow sensor platforms: standard testing type, high-sensitivity type (for biopharmaceutical materials), corrosion-resistant type (for corrosive samples), and energetic materials type (for chemical reactions). These sensors meet the requirements of different application scenarios and sample types.
  • Precision Temperature Control
  • The system utilizes circumferential heating technology and a proprietary dual-PID control system to ensure exact adherence to programmed temperature curves during heating/cooling processes. With a temperature control accuracy of ±0.01°C, it effectively minimizes thermal fluctuations that could compromise experimental results.
  • Ultralight Mineral Furnace
  • The silver-constructed furnace body delivers exceptional thermal conductivity and stability, ensuring precise temperature control and rapid thermal response. The pure silver material effectively minimizes heat loss while enhancing analytical efficiency, achieving uniform heating/cooling across samples. Its superior corrosion resistance extends instrument service life, accommodating diverse experimental environments.
  • Automatic Gas Switching Control
  • The multi-channel gas inlet device enables automatic gas switching during experiments. This integrated unit combines four or six gas lines into a single module to meet the demands of frequent gas changes across different testing procedures.
  • Gas Preheating Function
  • The furnace incorporates heated gas lines at the inlet ports, enabling gas preheating before entering the sample chamber. This design stabilizes experimental conditions and enhances testing efficiency.
  • Three High-Efficiency Cooling Systems
  • The DSC 600 is equipped with three high-efficiency cooling systems, offering versatile refrigeration options: water bath cooling, mechanical refrigeration, and liquid nitrogen cooling.
  • The water bath cooling system regulates furnace temperatures from 10°C to 600°C, ideal for scenarios not requiring cryogenic conditions, such as polymer melting point and crystallization temperature analysis. The mechanical refrigeration system covers a temperature range of -90°C to 450°C, widely used in polymer material analysis, including glass transition studies, crystallization kinetics research, and conventional low-temperature testing applications.
  • The liquid nitrogen cooling system utilizes the endothermic properties of evaporating liquid nitrogen for rapid cooling, with a furnace temperature range of -150°C to 600°C. It is primarily employed for ultra-low temperature research, such as metal alloy phase transitions, superconducting material analysis, and rapid quenching experiments, including amorphous material preparation and fast cooling process studies.

SOFTWARE

  • Experiment Program Setup Interface
  • Standard Functions
  • · Glass transition analysis
    (2-point or 6-point method)
  • · Onset/peak temperature determination
  • · Peak integration
  • · Melting peak analysis
  • · Crystallinity measurement
  • · Data smoothing
  • · Baseline correction
  • Optional Functions
  • Specific Heat Capacity:
    The system rapidly determines specific heat values by testing samples alongside reference materials with known heat capacity (e.g., sapphire) under identical conditions.

SPECIFICATIONS

Temperature Range -150~600°C
Temperature Accuracy ±0.1°C
Temperature Precision ±0.01°C
Program Rate 0.1~200°C/min
Cooling Mode Water Cooling Refrigerated Cooling Liquid Nitrogen Cooling
Maximum Temperature 600°C 450°C 600°C
Minimum Temperature Ambient Temperature -40°C or -90°C -150°C
Calorimetric Accuracy ±0.1%
Noise 0.5 μw
Gas Nitrogen, Argon, Helium, Compressed air, Oxygen, etc.
Sampling Frequency 10 Hz
Weight 27 lbs.
Dimensions 17 in(W) × 17 in(D) × 9.5 in(H)
  Options
Gas Controller 4 Channel Automatic Gas Switching
Software Functions Specific Heat Capacity

MATERIALS

  • Thermoplastics
  • Thermosets
  • Rubbers
  • Catalysts
  • Phenolics
  • Pharmaceuticals
  • Chemicals
  • Coals and other fuels
  • Nuclear Research
  • Foods
  • Cosmetics
  • Explosives

APPLICATIONS

  • Cold Crystallization Behavior of PET
  • The crystal growth and degree of crystallization depend on the polymer type, cooling rate, or isothermal aging time. The calculation method for crystallization enthalpy is the same as that for melting enthalpy. Cold crystallization is the process of crystal growth during heating. This exothermic event precedes crystal melting.
  • Glass Transition Analysis
  • The glass transition temperature (Tg) of polymers refers to the temperature range at which they transition from a rigid "glassy" state to a flexible "rubbery" state, significantly affecting their usability, particularly in elastomers. Understanding Tg is crucial for quality control, process optimization, ensuring product performance, and maintaining material consistency.
  • Phase Transformation of Nickel-Titanium Alloys
  • The Af temperature refers to the phase transition temperature of nickel-titanium alloys, marking the transformation from the high-temperature phase (a-phase) to the low-temperature phase (f-phase). In the high-temperature phase, the crystal structure of nickel-titanium alloy exhibits a cubic system, while in the lowtemperature phase it transforms into a monoclinic system. This phase transition temperature change gives nickel-titanium alloys their shape memory properties. These shape memory characteristics enable important applications across various fields, such as medical devices, aerospace, and mechanical engineering.

ACCESSORIES

  • Crucibles
  • Crucibles serve as sample containers in thermal analysis measurements, effectively protecting sensors and preventing measurement contamination. The selection of crucible type is critical for result quality. We offer various crucible options to meet different testing requirements, ensuring accurate and reliable measurement results.
  • Pellet Press
  • The crucible pellet press elevates sample encapsulation to higher performance and convenience, suitable for routine and hermetic testing of various materials. The standard model is specifically designed for solid sample crucibles, while the universal model handles both solid and liquid sample crucibles, offering greater flexibility for your experiments.
  • Fully Automated Chiller
  • The fully automated recirculating bath enables precise continuous temperature control within the range of -10°C to 90°C. When coupled with the water-cooled DSC 600 system, it achieves rapid furnace cooling, significantly enhancing experimental efficiency.
  • Gas Selector Accessory
  • The gas selector supports one-button switching across multiple gases, accommodating up to 4 input ports. It simplifies valve disassembly and assembly when sampling different gases, effectively minimizing leakage risks associated with manual handling. Additionally, the instrument features an automatic purging process, ensuring efficient gas line purification and seamless, automated switching between gases.

PDSC

  • Pressure Differential Scanning Calorimeter
  • The Pressure Differential Scanning Calorimeter (PDSC) is capable of conducting calorimetric tests under both high and low-pressure conditions. In practical applications, many raw materials and finished products are processed or used under high temperature and high pressure, making it essential to understand their performance under these extreme conditions. While traditional calorime-ters are effective in characterizing the physical and chemical properties of materials, the PDSC extends this characterization to extreme pressure environments. It allows for an in-depth analysis of the heat flow changes during phase transitions and chemical reactions under high or low pressure.
  • In a sealed crucible, changes in internal pressure can cause DSC test results to differ from those obtained under atmospheric pressure. The PDSC enables precise pressure control, which allows researchers to investigate the effects of varying pressures on samples and uncover thermal behavior differences in different environments. For material research in extreme test conditions, the PDSC offers superior capabilities in characterizing heat changes during reaction processes.
  • At the core of the PDSC is a high-performance heat flow sensor platform, specifically designed to study minute energy changes and the relationship between energy, temperature, and pressure.
  • Temperature Range -150-600°C
    Maximum Pressure 1000 psi
    Program Rate 0.1-200°C/min
    Gas Nitrogen, Argon, Helium, Compressed air, Oxygen, etc.

AMI Thermal Analysis Series Products

  • Differential Scanning
    Calorimeter
    (DSC)
  • Thermogravimetric
    Analyzer
    (TGA)
  • Simultaneous Thermal
    Analyzer
    (STA)
  • Thermomechanical
    Analyzer
    (TMA)

 

TGA 1000/1200/1500

INTRODUCTION

  • The TGA Series combines research-grade capabilities with an accessible price point, delivering high-performance thermal analysis tools without compromising on quality. Equipped with advanced high-sensitivity microbalances and compact, state-of-the-art furnaces, these instruments provide unparalleled precision, drastically reduce buoyancy effects, and ensure superior temperature responsiveness.
  • Renowned for their reliability and versatility, the TGA Series instruments are trusted across a wide range of industries, including plastics, rubber, adhesives, fibers, pharmaceuticals,environmental energy, petrochemicals, and food science. These instruments meet critical customer needs by enabling the characterization and analysis of parameters such as material decomposition temperatures, mass loss percentages, component contents, and residual mass.
  • TGA 1000/1200/1500

FEATURES

  • Proprietary Microbalance
  • The proprietary TGA microbalance combines high sensitivity, low drift technology, and thermal insulation design to deliver exceptional weighing accuracy. With a resolution as precise as 0.1 μg, it is ideal for high-precision measurements of trace samples. The low-drift technology minimizes the impact of environmental factors, ensuring stable data even in long-duration experiments, while reducing errors caused by drift. Additionally, the thermal insulation design protects the balance from external temperature fluctuations, maintaining internal temperature stability and ensuring reliable results, even in conditions of rapid temperature change or high heat.
  • Miniature Furnace
  • The compact heating furnace is designed to significantly minimize gas buoyancy effects, ensuring that dynamic curve drift in TGA remains under 25 μg without requiring additional blank tests. Additionally, the furnace delivers a rapid temperature response, achieving heating rates of up to 300°C/min, which dramatically shortens experimental time and enhances overall work efficiency.
  • Precise Temperature Control
  • The advanced heating technology combined with a dual PID control system ensures precise adherence to the set temperature curve during both heating and cooling processes. With a temperature control accuracy of ±0.1°C, this system significantly reduces the influence of temperature fluctuations, delivering highly reliable experimental results.
  • Wide Temperature Range
  • Multiple furnace options are available to meet the specific temperature requirements of different materials. With a maximum temperature capability of up to 1500°C, these furnaces are designed to satisfy the rigorous demands of both experimental and industrial applications.
  • Furnace Auto-Lift System
  • The instrument is equipped with an automatic furnace lifting system, simplifying experimental operations and preventing equipment damage or safety incidents caused by improper manual handling.
  • Water Cooling System
  • The fully automated recirculating bath provides precise and continuous temperature control, which effectively and rapidly reduces the TGA furnace temperature, significantly shortening the experimental time.
  • Automatic Gas Switching Control
  • The gas selector supports one-button switching across multiple gases, accommodating up to 4 input ports. The device features an integrated design, consolidating four gas channels into a single module to meet the need for frequent gas switching during different testing processes.
  • Evolved Gas Analysis
  • TGA can be combined with other analytical instruments for online monitoring and qualitative analysis of evolved gases, such as mass spectrometers (MS) or Fourier-transform infrared spectrometers (FTIR).

SOFTWARE

  • Experiment Program Setup Interface
  • Standard Functions
  • · 2-point or 6-point mass loss analysis
  • · Peak temperature analysis
  • · Weight loss step analysis
  • · Mass loss initiation point
  • · Residual mass calculation
  • · 1st and 2nd derivative analysis
  • · Data smoothing
  • ·Baseline subtraction
  • Optional Functions
  • High-Resolution thermogravimetric analysis:
    Enables effective separation of overlapping mass loss regions, improving resolution, and quickly obtaining experimental data over a wide tempera-ture range.

MATERIALS

  • Petrochemical products
  • Coal and other fuels
  • Explosives
  • Cosmetics
  • Thermoplastic materials
  • Thermosetting materials
  • Rubber
  • Coatings
  • Elastomers
  • Polymers
  • Pharmaceuticals
  • Food Products
  • Catalysts
  • Chemicals
  • Asphalt
  • Ceramics

SPECIFICATIONS

Temperature Range RT-1000°C RT-1200°C RT-1500°C
Temperature Accuracy ±0.5°C
Temperature Precision ±0.1°C
Program Rate 0.1-300°C/min 0.1~60°C/min
Cooling Mode Water Cooling
Resolution 0.1 μg
Measuring Range ±200 mg
Dynamic Baseline Drift ≤ 25 μg (No blank background subtraction)
Isothermal Baseline Drift ≤5 μg/h
Repeatability ≤10 μg
Weight 44 lbs.
Dimensions 16.3 in(W) × 14 in(D) × 16.6 in(H)
  Options
Gas Controller 4 Channel Automatic Gas Switching
Evolved Gas Analysis MS,FTIR,etc.

APPLICATIONS

  • Typical Applications
  • Thermal Stability
  • Thermal Pyrolysis
  • Oxidation Reactions
  • Dehydration Process
  • Decomposition
  • Process Kinetics
  • Combustion Process
  • Moisture Content
  • Residue and Ash Content
  • Dynamic Baseline Drift
  • In a typical TGA test, the sample mass may increase due to the "buoyancy effect" of the gas. However, the design of the miniature heating furnace ensures that the drift of the dynamic thermogravimetric curve remains below 25 μg, eliminating the need for baseline curve subtraction.
  • Weight Loss Step Analysis
  • The analysis software enables clear observation of the weight loss ratio and corresponding temperatures at each stage of the process. For instance, the thermogravimetric curve of hydrated calcium oxalate demonstrates three distinct stages. In the first stage, bound water evaporates, producing water vapor and leaving behind calcium oxalate. In the second stage, calcium oxalate decomposes into calcium carbonate and carbon monoxide. Finally, in the third stage, calcium carbonate further breaks down into calcium oxide and carbon dioxide.
  • High-Resolution TGA
  • The high-resolution TGA technology intelligently adjusts the heating rate in response to the sample's decomposition rate,effectively separating overlapping mass loss regions and enhancing resolution. This enables the rapid collection of experimental data across a wide temperature range. The exceptional resolution achieved with this advanced technology is particularly beneficial for analyzing the mass loss curve in TGA and the first derivative signals (DTG), providing highly detailed and accurate results.

ACCESSORIES

  • Crucibles
  • Crucibles serve as sample containers in thermal analysis measurements, effectively protecting sensors and preventing measurement contamination. The selection of crucible type is critical for result quality. We offer various crucible options to meet different testing requirements, ensuring accurate and reliable measurement results.
  • Mass Spectrometer
  • The Online Gas Mass Spectrometer is a quadrupole mass spectrometer specifically designed for the efficient collection and analysis of TGA evolved gases, with a mass range of 1-300 amu. It offers sensitivity at the parts-per-billion (ppb) level, ensuring precise analysis of low-concentration gases.
  • Fully Automated Chiller
  • The fully automated recirculating bath enables precise continuous temperature control within the range of -10°C to 90°C. When coupled with the water-cooled DSC600 system, it achieves rapid furnace cooling, significantly enhancing experimental efficiency.
  • Gas Selector Accessory
  • The gas selector supports one-button switching across multiple gases, accommodating up to 4 input ports. It simplifies valve disassembly and assembly when sampling different gases, effectively minimizing leakage risks associated with manual handling. Additionally, the instrument features an automatic purging process, ensuring efficient gas line purification and seamless, automated switching between gases.

AMI Thermal Analysis Series Products

  • Differential Scanning Calorimeter(DSC)
  • The DSC is a device used to measure the energy changes absorbed or released by a sample during variations in time or temperature. The DSC sensor is a heat flow measurement platform employing specialized technology, designed to deliver exceptional performance and testing reliability. Examples of measurements conducted using DSC include enthalpy of melting, glass transition, crystallization, purity, and specific heat capacity.
  • Thermogravimetric Analyzer(TGA)
  • The TGA measures changes in the weight of a sample as a function of temperature or time. This product supports the editing of multiple program segments, allowing for the design of complex experiments involving heating, cooling,or isothermal conditions. It also features automatic gas switching during temperature ramps, while its vertical supension design ensures stable and accurate weight readings throughout the experiment. The TGA's micro-furnace provides rapid response to temperature changes and enables quick cooling between multiple experiments.
  • Simultaneous Thermal Analyzer(STA)
  • AMI introduces anew generation of high-performance STA, featuring a microbalance with 0.1 μg resolution, advanced control algorithms, and structural design. The STA is ideally suited for evolved gas analysis, capable of precisely capturing minute mass changes and thermal effects. It is also equipped with an atmosphere control system that provides specific gas environments, aiding in the simulation of real-world conditions. The STA is flexibly configurable to meet all your specific thermal analysis testing needs.
  • Thermomechanical Analyzer(TMA)
  • Thermal expansion is a primary cause of mechanical stress and electronic component failure. The TMA can accurately determine the glass transition temperature and stress relief points of materials, identify critical points that may lead to delamination, and ensure the stability of electronic performance. This new thermomechanical analyzer features a simple and robust design, specifically tailored for measuring the expansion of small components and the low expansion rates of circuit boards and component materials.

 

STA 650 1000 1200 1500

INTRODUCTION

  • AMI is pleased to introduce its next-generation Simultaneous Thermal Analyzer (STA), a state-of-the-art instrument designed for advanced thermal analysis. Incorporating a 0.1-microgram balance resolution, sophisticated control algorithms, and an innovative hang-down design, this analyzer delivers exceptional precision and reliability in an affordable, high-performance system.
  • The STA Series enables simultaneous Thermogravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC)/Differential Thermal Analysis (DTA) on a single sample within a single run. Built for reliability and precision, the STA delivers comprehensive thermal profiles without the need to run multiple experiments—saving you both time and sample material.
  • Engineered for quality control, routine testing, academic research, and industrial R&D, the STA Series combines robust construction with user-friendly intuitive software, offering a cost-effective solution for high-precision thermal analysis.
  • The STA is controlled by the Infinity Pro Thermal Analysis software. This unique Windows based software offers a very simple interface with all the features you need to analyze your thermal data.
  • STA Simultaneous Thermal Analyzer

MATERIALS

  • ● Polymers
  • ● Chemicals
  • ● Petrochemicals
  • ● Polymorphs
  • ● Superconductors
  • ● Ceramics
  • ● Glasses
  • ● Composites
  • ● Metals
  • ● Engineered alloys
  • ● Pharmaceuticals
  • ● Catalyst Research
  • ● Building Materials
  • ● Propellants
  • ● Explosives
  • ● Electronic Components
  • ● Coals & other fuels
  • ● Catalysts
  • ● Nuclear Science Materials
  • ● Food and Biomaterials

FEATURES

  • True Hang-Down Balance Design
  • Industry-leading stability, sensitivity, and long-term drift resistance for reliable and repeatable measurements without the need for buoyancy corrective experiments.
  • High Sensitivity Microbalance
  • Sub-microgram-level accuracy across a broad temperature range, providing confidence in your thermal and mass loss data.
  • 24-Bit Resolution
  • High-precision measurement of temperature, delta T, and weight with minimal noise and high digital fidelity.
  • Small Swept Volume Furnace Cup (7.5mL)
  • Enhances temperature uniformity and gas exchange efficiency.
  • Simultaneous TGA/DSC or DTA
  • Perform thermogravimetric and calorimetric analyses in a single run— ideal for decomposition, oxidation, and phase transitions.
  • Dual Purge Gas System
  • Separate channels for purge and protective gases allow for fine control of the experimental atmosphere.
  • Broad Temperature Range
  • Furnace operation up to 1500°C under inert, oxidizing, or reducing gas environments.
  • Motor-Driven Furnace Lift
  • Ensures automated, smooth movement of the furnace for consistent sample positioning.

OPTIONS

  • Evolved Gas Analysis (EGA) Compatibility
  • Interface with mass spectrometry (MS) or FTIR systems for evolved gas studies during thermal decomposition.
  • 4-Gas Selector System
  • Automates delivery of up to four different gases for programmable switching during analysis.
  • Sub-Ambient System (650°C Model)
  • Low-temperature furnace models support experiments starting below room temperature
  • High-Temperature Flexibility
  • Optional DSC-only high-temperature mode to allow DSC-only to 1,500°C
    Optional TGA-only high-capacity mode for larger or reactive samples

EXAMPLES

  • Barium Chloride
  • This is an example of a reference material that shows temperature and enthalpy accuracy. In addition, this represents a good example of a fused peak analysis.
  • Calcium Oxalate
  • Calcium Oxalate is an excellent demonstration material for both DSC and TGA. This sample was run in the presence of Oxygen. The first DSC peak has an associated weight loss and represents bound water.
  • STA data analysis

SPECIFICATIONS

  • Temperature -40°C-650°C Ambient to 1200°C Ambient to 1500°C
    Programmed Rate 0.1-100 °C/min 0.1-40 °C/min
    DSC Sensitivity <1 μW <4 μW
    TGA Range 400 mg
    TGA Readability 0.1 μg
    Thermocouple Type K Type R
    DSC/DTA mode Yes

TMA 800

INTRODUCTION

  • The TMA 800 is built on a proven vertical design that incorporates an advanced Oil Float Suspension System, delivering the stability and precision required for accurate measurement of thermal expansion, glass transition, and other thermomechanical properties across a wide range of materials.
  • Engineered for both performance and ease of use, the TMA 800 provides exceptional data quality for analyzing coefficients of thermal expansion (CTE), stress relaxation, and dimensional change. It is ideally suited for high-reliability applications in electronics, composites, advanced polymers, and more. With a wide operating temperature range from -90 °C to 800 °C and multiple test modes available, the TTMA 800 offers outstanding versatility to meet a broad range of application needs.
  • Thermal expansion is a primary cause of mechanical stress and failure in electronic components, PCB assemblies, and multilayer structures. Accurately determining the glass transition temperature—the point at which softening and stress relief begin—or the onset of delamination is critical to product development, performance, and reliability in thermal environments.
  • The TMA 800 is a rugged, easy-to-use system designed for both routine testing and advanced research. It features a motorized furnace lift for smooth, safe repositioning after loading, with integrated position sensors to ensure operator protection. Its all-metal furnace is built to deliver thousands of hours of failure- free performance, while its vertical geometry supports samples ranging from a few microns to over a centimeter tall—ideal for measuring both small components and low-expansion materials such as circuit boards.
  • Whether you're characterizing high-performance materials or qualifying components for harsh service environments, the TMA 800 offers the accuracy, reliability, and usability demanded by today’s materials labs.
  • TMA 800

FEATURES

  • True Vertical Alignment for Accuracy
  • Unlike most TMA units that use U-shaped geometry for convenience, the TMA 800 features a direct, vertical in-line design. This configuration minimizes friction, ensures uniform force application, and reduces noise and sample deformation—delivering superior measurement precision.
  • Oil Float Suspension System (Exclusive to the TMA 800)
  • During softening or transition, even slight mechanical noise or unintentional force can distort results. The Oil Float Suspension System supports the full weight of the probe and force coil, ensuring that only the intended force is applied. This system also dampens external vibrations, ensuring greater accuracy and protection of delicate materials.
  • Interchangeable Probes & Sample Holders
  • Easily switch between expansion, flexure, and penetration probes to meet a wide range of testing requirements. A specialized accessory allows for convenient mounting of films, fibers, and other delicate specimens, supporting industry-standard testing methods.
  • Advanced, Computerized Operation
  • The TMA 800 is fully computerized, with most functions controlled via an intuitive software interface. The pre-calibrated temperature sensor provides precise temperature readings, and calibration routines are straightforward—even for fast-scanning or complex samples. Software capabilities include:
  • • Real-time data display
    • Automatic zeroing and sample height reading
    • Curve optimization and overlay
    • Program archiving, comparison, and automated calculations
  • Cross-section of the TMA
  • The TMA 800 is an outstanding solution for laboratories seeking a cost-effective yet high- performance instrument to meet regulatory requirements for thermal expansion—especially in electronics, aerospace, composites, and other sensitive industries where dimensional stability is critical. Here are a few ways the TMA 800 is engineered for precision thermal analysis:
  • • The cold sink surface is cooled by a heat exchanger that easily connects to an external chiller using a single-bolt attachment, simplifying low-temperature operation.
    • The 40 mm furnace height provides an exceptionally wide and uniform temperature zone, ensuring consistent heating across the full sample length.
    • A high-resolution Linear Variable Differential Transformer (LVDT) sensor offers both the sensitivity to detect micron-level changes and the range to track large dimensional shifts.
    • The submerged float supports the full weight of the sample probe and core rod while dampening external vibrations and protecting sensitive quartz components.
    • The core rod and probe are fully supported by AMI’s unique Oil Float Suspension System, delivering friction-free motion and unmatched force control during softening transitions.
  • Whether you're focused on glass transition detection, CTE measurement, or structural deformation, the TMA 800 is optimized to deliver the accuracy, repeatability, and confidence your lab demands.

SPECIFICATIONS

  • Model TMA 800
    Isothermal Stability ± 0.4 °C
    Probe control Oil float System and Electronic Force
    Thermocouple Type Type K Nickel-Chromel
    Temperature Range Ambient °C to 800 °C (-80 °C to 800 °C with RCS System)
    Temperature Program 0.1 °C/min to 60 °C/min
    Temperature Accuracy 1°C
    Temperature Precision 1°C
    Maximum Sample Size Up to 10 mm in length
    Maximum Load 2N
    Cooling System Water Cooling (Standard); RCS Cooling (Option)
    Testing Geometries Expansion, Tensile, Penetration, 3 Point Bending, Compression, Dilatometer
    Power Requirements 100-120/220-240V, 60 / 50Hz
    Options Multi-channel Gas Inlet Controller (Gas switching for up to four gases)
  • TMA Data

 

Lattice Series

INTRODUCTION

  • The Lattice Series redefines benchtop X-ray diffraction by combining high-power performance with compact design. Equipped with a powerful 600 W (Lattice Mini) or 1600 W X-ray source and a high-efficiency, direct-read 2D photon detector, the Lattice Series delivers exceptional data intensity and accuracy—making it ideal for demanding analytical environments.
  • Available in three configurations—Lattice Mini, Lattice Basic, and Lattice Pro—this series accommodates a wide range of technical and budgetary needs, from simple phase identification to complex in-situ studies. All models offer excellent signal-to-noise ratio and fast scan speeds, providing lab-grade data from a desktop system.
  • Whether you're analyzing complex powders, crystalline materials, or conducting highthroughput measurements, the Lattice Series provides lab-grade results with speed, power, and precision—all in a desktop footprint.
  • Lattice Series Instrument

MODEL SERIES

  • The Lattice Mini is the ideal entry point for high-quality X-ray diffraction. Designed for users who need reliable phase identification and material characterization in a truly space-saving format, the Lattice Mini delivers powerful performance in a compact, affordable package.
  • Ideal for:
  • • University and teaching laboratories
    • Small research groups
    • Routine QA/QC in ceramics, metals, and minerals
    • Rapid phase screening and basic material studies
  • The Lattice Basic is designed for laboratories that require dependable, high-throughput diffraction without the complexity of advanced custom configurations. With high angular resolution and a direct-read 2D photon detector, the Lattice Basic delivers fast, accurate results across a wide range of powder samples. It’s an excellent choice for users who prioritize precision, speed, and reliability—at an efficient price point.
  • Ideal for:
  • • QA/QC labs
    • Materials characterization
    • Educational and institutional research
    • Cement, ceramics, metals, and pharmaceuticals
  • The Lattice Pro is built for the most demanding applications. Featuring Theta–Theta geometry for enhanced sample stability and accessory support, it enables precise, high-performance analysis for advanced materials, coatings, and stress testing.
  • Ideal for:
  • • Advanced R&D environments
    • Dynamic experiments
    • Residual stress analysis
    • Film, coating, and thin-layer characterization
    • Battery and energy materials research

KEY FEATURES

  • • High-Power X-ray Source
  • Choose between 600 W or 1600 W configurations for high-intensity data collection and rapid scanning.
  • • 2D Photon Direct-Read Detector
  • A 256 × 256 pixel array captures sharp, high-resolution diffraction patterns with an excellent signal-to-noise ratio.
  • • Exceptional Angular Accuracy
  • Achieve step sizes as small as ±0.01° 2θ and ensure a consistent peak matching with standard reference materials.
  • • Flexible Goniometer Options
  • Theta–2Theta geometry for standard analysis (Mini & Basic) or Theta–Theta for enhanced sample stability (Pro).
  • • Fast, Reliable Scanning
  • Obtain full-spectrum data in minutes—ideal for routine QA and high-throughput labs.
  • • Compact Benchtop Design
  • Fits seamlessly into modern lab environments without sacrificing performance or requiring floor space.
  • • Expandable Functionality (Lattice Pro)
  • Supports advanced modules for residual stress testing, high-temperature stages, in-situ battery studies, and thin film analysis.
  • • User-Friendly Operation
  • Intuitive software and streamlined hardware design simplify training and daily use.

PERFORMANCE EXAMPLES

  • Miller Indices Theoretical Peak Measured Peak Difference
    Position Position
    012 25.579 25.577 0.0020
    104 35.153 35.15 0.0030
    116 57.497 57.497 0.0000
    1010 76.871 76.872 0.0010
    0210 88.997 88.996 -0.0010
    0114 8116.612 116.61 -0.0020
  • Comparison of Theoretical Peak Positions and Measured Peak Positions for Corundum Standard Sample
  • Instrument Repeatability Measurement
  • XRD Spectrum of Ternary Materials Black represents regular measurement mode data, and blue represents fluorescence-free mode data.
  • Test Data for Corundum Powder (10°/min)
  • Graphitization Degree Measurement
  • Measurement Spectrum for Silicon Nitride Ceramic
  • Reflective In-Situ Battery Measurements

TECHNICAL PARAMETERS

  • Model Lattice Mini Lattice Basic Lattice Pro
    X-ray tube 600 W 1600 W
    X-ray tube target material Standard Cu target, Co target is optional
    Theodolite Theta / 2theta geometry, the radius of the theodolite is 158 mm Theta / 2theta geometry, the radius of the theodolite is 170 mm Theta / theta geometry, the radius of the theodolite is 170 mm
    Maximum scanning range -3 - 156°
    Theta Minimum step size ±0.01°
    Detector Photon direct-read two-dimensional array detector
    Detector energy resolution 0.2
    Volume and Weight L 25.6 in (650 mm) × W 19.7 in (500 mm) × H 15.8 in (400 mm), 132 lbs (60 kg) L 35.5 in (900 mm) × W 26.8 in (680 mm) × H 21.7 in (500 mm), 220 lbs (100 kg)
    Sample stage Standard chip stage
    Options N/A Five-bit injector; In situ battery test accessories; SFive-bit injector; In situ battery test accessories; High temperature sample station: can be customized according to customer requirements, e.g., RT-600°C/RT- 1000°C; Residual stress measuring fixture (can be customized); Film sample stage: Size: 2.4 in (60mm) × 2.4 in (60mm) (can be customized)

AMI-Sync Series

INTRODUCTION

  • The AMI-Sync Series is a fully automated, high-performance line of gas physisorption analyzers designed for rapid and accurate surface area and pore size characterization of porous and non-porous materials. Whether analyzing catalysts, zeolites, MOFs, or advanced battery materials, the AMI-Sync Series delivers robust vacuum-volumetric measurement systems backed by intuitive software and comprehensive support for both standard and advanced adsorption techniques.
  • Available in flexible 1-, 2-, or 4-station configurations, the AMI-Sync Series features a common P₀ measuring transducer and supports simultaneous saturation vapor pressure measurements. Each unit is built for high-throughput performance, with options for a dedicated pressure transducer per station to maximize speed, or a shared sensor setup for cost efficiency. A single large-volume dewar supports multiple stations simultaneously, offering an ideal solution for space-conscious laboratories with demanding workloads.
  • AMI-Sync 400 Series Instrument

KEY FEATURES

  • Customizable Configuration for Throughput Analysis Needs
  • The AMI-Sync series offers a scalable solution with up to four high-resolution measurement stations for precise pore size and surface area analysis. For increased throughput, additional instruments can be linked via LAN, expanding to 12 analysis ports with centralized and remote-control capabilities.
  • Extended Analysis Duration
  • AMI-Sync analyzers are equipped with large 3-liter Dewar flasks that allow over 90 hours of continuous analysis. The system supports live refilling during experiments, ensuring uninterrupted data collection during long runs and complex isotherm acquisitions.
  • High Sensitivity & Reproducibility
  • The AMI-Sync Series delivers precise and reliable surface area and porosity data, with a BET detection limit as low as 0.1 m² absolute and 0.01 m²/g specific. It offers outstanding reproducibility—within 1% on standard reference materials like BAM P115—ensuring confidence in repeated analyses.
  • Precision-Engineered Hardware
  • Built with stainless steel and vacuum-brazed manifolds, the system features ultra-durable bellows valves rated for over 5 million cycles. Temperature control maintains ±0.05 °C stability, while 32-bit pressure sensors provide high-resolution, accurate data capture.
  • Cryo TuneTM (Optional Feature)
  • Unlock advanced temperature control with Cryo TuneTM, an optional low-temperature cold bath system designed for precision adsorption studies. Fully integrated with Sync software, Cryo TuneTM allows users to effortlessly conduct adsorption isotherm measurements across a range of temperatures.
  • Optimized Manifold Contamination Control
  • A two-step filtration system protects the manifold from particulates reducing contamination risks and extending instrument life. Combined with stainless steel construction and high-cycle bellows valves, the system ensures clean, reliable operation even in high-throughput environments.
  • Compact & Lab-Ready
  • All models share a compact footprint of 51 ×53 × 93 cm, making them ideal for space-conscious labs. Despite their compact size, Sync analyzers are fully equipped for both research-grade and industrial applications, offering power, durability, and precision in one system.

SOFTWARE

  • Sync Series analyzers are driven by a multilingual, user-friendly software suite that supports:
  • • Control of up to 8 instruments from a single PC
    • Built-in method libraries
    for fast setup and repeatability
    • Customizable analysis profiles with real-time system feedback
    • Automated leak detection and guided maintenance routines
    • CFR 21 Part 11-ready
    sample tracking, including ID and method history
    • Visual instrument status interface for monitoring analysis in progress
  • Additional capabilities include void volume correction, supercritical P0 handling, temperature control with CryoTune, and compatibility with up to 6 gases per station.
  • Isotherm
  • 3-stage evacuation to prevent sample fluidization
  • Main software screen
  • Interactive software screen
  • Data Analysis Capabilities:
  • Isothermal absorption and desorption curve
    BET specific surface area (single and multiple point)
    Langmuir surface area
    Statistical thickness surface area. (STSA)
  • HK pore size analysis
    SF pore size analysis
    NLDFT pore size distribution
    Total pore volume
    t-plot analysis

SPECIFICATIONS

Model AMI-Sync
Specific Model 110 210 220 420 440
Analysis Ports 1 2 2 4 4
p0 Transducer 1 1 1 1 1
Analysis Pressure Transducer 1 1 2 2 4
Surface Area ≥ 0.0005 m2/g
Pore Size 0.35-500 nm
Pore Volume ≥ 0.0001 cm3 /g
Pump Mechanical pump(minimal 5.0×10-4 mmHg)
p/p0 10-5-0.998
Accuracy PTs 1000 mmHg(+/-0.2%F.S.)
Adsorbates N2,CO2,Ar,Kr,H2,O2,CO,NH3,CH4
Dimensions 51 × 53 ×93 cm (16.1 x 20.8 x 36.6 inches) All same dimensional size
Weight 45 kg | 99 pounds (maximum depending on configuration)

RuboSORP MPA Series

INTRODUCTION

  • The RuboSORP MPA is a cutting-edge, high-pressure volumetric adsorption instrument designed for accurate and reliable pressure-composition-temperature (PCT) measurements up to 200 bar. Engineered for precision and efficiency, it provides deep insights into gas adsorption behavior, enabling researchers to analyze surface properties, storage capacity, and cycling kinetics with unmatched accuracy.
  • With its versatile capabilities, the RuboSORP MPA is the ideal solution for:
  • ✔ Hydrogen storage material evaluation
    ✔ Shale gas and coal bed methane studies
    ✔ CO₂ capture and sequestration research
    ✔ Air purification and adsorbent performance testing
  • Built for precision, reliability, and multi-sample efficiency, the RuboSORP MPA empowers scientists and researchers in developing next-generation energy and environmental solutions. Advance your research with the RuboSORP MPA—where accuracy meets innovation.
  • High-Pressure Volumetric Sorption:
  • PCT and other gas adsorption/ desorption isotherms
    Cycling PCT isotherm measurements
    Adsorption kinetics
    Cycling kinetic measurements
    Dead volume measurements
  • RuboSORP MPA Multiport High Pressure Sorption Analyzer
 

KEY FEATURES

  • Oven temperature control
  • Oven temperature control system with a range of RT-50°C and a temperature accuracy of ±0.1°C, designed to mitigate the impact of ambient.
  • Additional volume chamber
  • Multiple standard volume chambers are available (100 ml, 200 ml, 500 ml, 1000 ml) for the acquisition of more precise kinetic data.
  • Diverse Sensor Configurations
  • The MPA system allows multiple stations to share sensors while also supporting the complete independence of up to three stations, offering both cost- effectiveness and high efficiency.
  • Safety design
  • The MPA features over- temperature and over- pressure alarms with automatic shutdown in alarm situations.

SOFTWARE

  • RuboSORP MPA software interface
  • The MPA is equipped with a user-friendly software interface that allows programming of all measurement parameters. The system calculates the amount of gas adsorbed by the sample in real time. Adsorption data is displayed online and fitted using appropriate isotherm models.
  • The MPA allows for testing up to three sample materials across a wide range of pressures and temperatures with high efficiency. The instrument is fully automated and intuitive, requiring no user supervision during operation.

APPLICATIONS

  • PCT curve of LaNi5 at 40°C
  • Cyclic testing of activated carbon at 40°C
  • Isotherms of activated carbon at 40°C
  • Typical Materials: Solid-State H2 Storage

SPECIFICATIONS

Analysis Ports 1/2/3
Pretreatment In-situ
Pressure range Vacuum- 200 bar
Pressure sensor configuration Optional ranges: 0-10 bar, 0-50 bar, 0-100 bar, 0-200 bar; Accuracy: 0.01% FS.
Gases Non-corrosive gases: H2, CO2, CH4, N2, etc.
Temperature range RT - 500°C;
-196°C to 0°C (Option); -10°C to 95°C(Option)
Custom higher temperatures: Available upon request.
Sample tube volume Standard: 10 ml (Other volume is optional)
Sample tube temperature Detection accuracy: ±0.01°C
Control accuracy: 0.1°C
Oven temperature control Air bath, 30~50°C.
Additional volume chamber Up to 2 chambers, multiple volumes available (Option)
Vacuum system Mechanical pump + turbo molecular pump (minimal 10-8 Pa, Option)
Model 1S 2S 2P 3S 3P
Number of pressure sensors including manifold 2 4 2 5 2
Available Options BET Capabilities
*Additional pressure sensors can be added per station

 

Switch-6

  • The automatic multi-channel gas inlet controller, Switch-6, features an integrated design, enabling one- button switching among multiple gases and supporting up to six input ports. Users can select any gas path for output as needed, making it ideal for applications requiring frequent gas changes during various testing procedures.
  • This device is highly compatible, designed to work seamlessly with the full range of AMI instruments and a wide variety of systems from other manufacturers.
  • Safety
  • Features a streamlined valve disassembly and assembly when switching between different gases, significantly reducing the risk of leakage from manual operations. Additionally, a corrosion-resistant version is available upon request to accommodate more demanding environments.
  • Simplicity
  • Enables automatic gas switching with a single button press. It also performs automatic pipeline purging, preventing residual gases from affecting the accuracy of subsequent experimental results.
  • Flexibility
  • Supports six input ports and one output port, with the option to cascade multiple units—allowing for 6, 12, 18, or more gas paths as needed.
  • Automatic Multi-channel Gas Inlet Controller
  •   Switch-6
    Number of ports 6 (12, 18 are optional)
    Tubing size 1/8 inch
    Pressure Near atmospheric
    Gas types N2, H2, Ar, and other gases (corrosive gases such as H2S, NH3, HCl, etc., are available as options)
    Dimensions and weight L 28.7 in (730 mm) ×
    W 9.5 in (240 mm) ×
    H 10.0 in (253 mm),
    11 lbs (5 kg)

 

InSight Series

INTRODUCTION

  • Soft-pack (pouch) batteries play a critical role in both cutting-edge research and next-generation commercial energy storage. Yet studying their internal behavior during charge and discharge— especially over long cycles—has been limited by the constraints of traditional in-situ XRD methods. The InSight Series changes that.
  • This dedicated in-situ Transmission X-ray Diffractometer is purpose-built for soft-pack battery analysis. Unlike conventional reflective-style molds, the InSight Series uses a vertical transmission geometry to collect diffraction data from both the anode and cathode simultaneously—across the full cell thickness.
  • Paired with a high-intensity 1600 W Mo X-ray source, a photon-counting 2D array detector, and precision temperature control from -30°C to 300°C, the InSight Series offers unmatched resolution, speed, and stability for real-time battery material studies.
  • InSight Series

KEY FEATURES

  • • 1600 W Molybdenum X-ray Tube
  • Delivers strong, high-penetration X-rays optimized for soft-pack battery materials.
  • • Photon-Counting 2D Array Detector
  • High-efficiency, low-noise capture of fine diffraction details, with fast scan times.
  • • Transmission Geometry
  • X-rays enter through one side of the pouch and exit through the opposite—ideal for full-cell analysis.
  • • Temperature-Controlled Sample Stage
  • Wide range (-30°C to 300°C) supports studies of degradation, performance, and thermal failure.
  • • Precision Goniometer
  • Theta–2Theta geometry with a 144 mm radius for stable, accurate angular scanning.
  • • Compact Footprint
  • Lab-friendly design with powerful capability: 900 × 680 × 550 mm, 100 kg.
  • Why In-situ Transmission XRD for Soft-Pack Batteries?
  • • True Long-Term Cycling:
  • Unlike coin cell molds, soft-pack batteries offer superior sealing and stability for thousands of cycles.
  • • Full-Depth Material Insight:
  • Vertical transmission geometry collects diffraction data through the entire pouch— enabling dual-electrode analysis.
  • • Superior Resolution at Any Thickness:
  • Focused beam transmission ensures peak clarity, even in thicker pouch cells.
  • • Thermal Behavior Included:
  • Variable-temperature stage enables in-situ measurements at both sub-zero and high- temperature conditions.
  • • Electrochemistry + Structure, Together:
  • Seamless integration with an electrochemical workstation allows simultaneous control and data acquisition during charging/discharging.
  • In-situ Transmission XRD Optical Path Diagram

PERFORMANCE EXAMPLES

  • From anode intercalation to cathode degradation and thermal behavior, these performance examples demonstrate the system’s ability to deliver high-resolution, high-confidence data—in real time, inside working soft-pack batteries.
  • In-situ Transmission XRD Data Display for Lithium Cobalt Oxide Soft-Pack Battery
  • Single Data Measurement Time: 300 seconds
  • Variation in LiFePO4 and FePO4 Phase Content
  • In-situ Changes of NCM 003 Peak
  • In-situ Changes of Graphite Negative Electrode inSoft-Pack Battery
  • Variation in NCM Unit Cell Parameter a
  • Variation in NCM Unit Cel Volume
  • Variation in NCM Unit Cell Parameter c
  • In-situ Transmission XRD Data for Lithium Iron Phosphate Soft-Pack Battery
  • In-situ Transmission XRD Data for Lithium Iron Phosphate Soft-Pack Battery
  • LiFePO4 Phase Confirmation
  • Phase Content and Structural Information Obtained from XRD Fitting

SPECIFICATIONS

  • X-ray tube 1600 W
    X-ray tube target material Mo
    Theodolite Theta / 2theta geometry, the radius of the theodolite is 144 mm
    Detector Photon-Counting two-dimensional array detector
    Maximum scanning range 0° - 150°
    2Theta minimum step size ±0.01°
    Volume and Weight L 35.4 in (900 mm) × W 26.8 in (680 mm) × H 21.7 in (550 mm), 220.5 lbs (100 kg)
    Sample stage Temperature-controlled sample stage for pouch cells (0°C ~ 300°C)

Meso 112/222

INTRODUCTION

  • The AMI-Meso112/222 Series is engineered for high-precision surface area and pore size characterization of powdered materials. This series comprises two models, Meso 112 and Meso 222, both integrated with 1000 torr pressure transducers at each analysis station for accurate BET surface area determination and mesopore size distribution analysis.
  • Each analysis port is equipped with an in-situ degassing module capable of heating samples up to 400°C, ensuring efficient removal of adsorbed contaminants prior to analysis. This in-situ degassing eliminates the risk of contamination associated with sample transfer. Additionally, when multiple stations are utilized, each operates independently, allowing for simultaneous yet discrete analyses of different samples.
    • Structural distribution diagram of Meso 222

KEY FEATURES

  • Module Design for Minimal Dead Volume
  • The internal gas path design of the instrument adopts a unique integrated metal module design, which not only reduces the internal dead volume spacebut also helps mitigate possible leaks.
  • Saturated Vapor Pressure P0
  • An independent P₀ pressure transducer is configured at 133 kPa for P₀ value testing,enabling real-time P/P₀ measurement for more accurate and reliable test data. Alternatively, an atmospheric pressure input method can be used to determine P₀.
  • Datasheet
  • Independent analysis ports
  • With independent analysis ports, the system employs a unique vacuum control logic that allows each station to operate without disruption, even when using a single mechanical pump or pump group.This enables simultaneous, independent experiments, meeting diverse adsorbent testing needs while ensuring high efficiency.
  • Liquid Nitrogen Dewar
  • The use of 1 L Dewar flasks in conjunction with a sealed cover ensures a stable thermal profile along the entire length of both the sample tubes and P₀ tubes throughout the testing process.
  • Sample Preparation
  • Equipped with two in-situ degassing ports, enabling simultaneous degassing and analysis. Each port offers independent temperature control from ambient to 400°C, ensuring precise sample preparation.
  • High Accuracy Pressure Transducers
  • Equipped with 1000 torr pressure transducers, the Meso Series enables precise physical adsorption analysis, achieving a partial pressure (P/P₀) as low as 10 -² for nitrogen (N₂) at 77 K.
  • Datasheet
  • Optimized Manifold Contamination Control
  • This system features a multi-channel, adjustable, and parallel vacuum design with segmented vacuum control. This setup effectively prevents samples from being drawn up into the analyzer therefore preventing manifold contamination.
  • Thermal Stabilization
  • A core rod in the sample tube reduces deadvolume and stabilizes the cold free space coefficient, while an iso-thermal jacket maintains a constant thermal profile along the tube. Additionally, automatic helium correction ensures precise calibration for any powder or particulate material, minimizing temperature- related deviations during analysis.

SOFTWARE

  • PAS Software is an intelligent solution for operation control, data acquisition, calculation, analysis, and report generation on the Windows platform. It communicates with the host via the LAN port and can remotely control multiple instruments simultaneously.
  • PAS Software adopts a unique intake control method, optimizing pressure in the adsorption and desorption processes through a six-stage setting, which improves testing efficiency.
  • Datasheet
  • Changes in pressure and temperature inside the manifold can be directly observed in the test interface, providing convenience for sample testing and instrument maintenance. The current state of analyzer can be intuitively understood with the indicator light and event bar.
  • Each adsorption equilibrium process is dynamically displayed on the test interface. Adsorption characteristics of the sample can be easily understood.
  • A clear and concise report setting interface, including the following:
  • Adsorption and desorption isotherms
  • Single-/Multipoint BET surface area
  • Langmuir surface area
  • STSA-surface area
  • Pore size distribution according to BJH
  • T-plot
  • Dubinin-Radushkevich
  • Horvath-Kawazoe
  • Saito-Foley

TYPICAL ANALYSIS RESULTS

  • The specific surface area test results of iron ore powder are presented in the figure below. As a material with very small specific surface area, the repeatability error is only 0.0015 m2/g in the test results.
  • Datasheet
  • Datasheet
  • Analysis value of pore size distribution in activated carbon materials as follows:
  • Datasheet
  • Datasheet

SPECIFICATIONS

Model AMI-Meso 112 AMI-Meso 222
Analysis Ports 2 2
P0 Transducer 2 2
AnalysisPressure
Transducer
1 2
Accuracy PTs 1000 torr
Pump 1 Mechanical pump (ultimate vacuum 10-2 Pa);
P/P0 10-4- 0.998
Surface Area ≥ 0.0005 m2/g, test repeatability: RSD ≤ 1.0%
Pore Size 0.35-500 nm, test repeatability: ≤0.2 nm
Pore Volume ≥ 0.0001 cm3/g
Degassing Ports 2 in-situ
Adsorbates N2, CO2, Ar, Kr, H2, O2, CO, CH2, etc.
Cold Trap 1
Volume and Weight L 34.5 in (870 mm) × W 22.5 in (570 mm) × H 35.0 in (890 mm), 188 lbs (85 kg)
Power Requirements 110 or 200-240 VAC, 50/60 Hz, maximum power 300 W

APPLICATIONS

Applied Field Typical Materials Details
Material Research Ceramic powder, metal powder, nanotube According to surface area value of nanotube, hydrogen storage capacity can be predicted.
Chemical Engineering Carbon black, amorphous silica, zinc oxide, titanium dioxide Introduction of carbon black in rubber matrix can improve mechanical properties of rubber products. Surface area of carbon black is one of the important factors affecting the reinforcement performance of rubber products.
New Energy Lithium cobalt, lithium manganate Increasing surface area of electrode can improve Electrochemical reaction rate and promote iron exchange in negative electrode.
Catalytic Technologies Active alumina oxide, molecular sieve, zeolite Active surface area and pore structure influence reaction rate.

 

Prep Series

Prep 8A- VACUUM DEGASSER

  • The Prep 8A features two independent working modules, each with four degassing ports, allowing simultaneous preparation of up to eight samples. Each module operates with independent temperature and time controls, enabling flexible and parallel sample degassing.
  • A multi-stage vacuum pumping system, regulated by an internal pressure transducer, prevents sample elutriation, controls switching pressure, regulates nitrogen backfill pressure, and maintains precise pressure control during furnace descent. Programmable temperature ramping and a built-in cooling fan ensure efficient, precise, and controlled thermal treatment.
  • The system is operated via a 7-inch touchscreen interface with automatic parameter memory, streamlining operation and enhancing usability.
  • Use-Case:
  • High-capacity vacuum degasser with vertical configuration; ideal for labs prioritizing throughput, thermal uniformity, and complete automation.
  • Prep 8A
  • Model Prep 8A
    Temperature RT-400°C

    Control accuracy

    ±1°C
    Degassing port 8
    Pump 1 mechanical pump
    Heating method Programmed temperature ramping (Optional)
    Dimensions and weight L 17.0 in (430 mm)
    W 16.0 in (405 mm)
    H 28.5 in (725 mm)
    80 lbs (36 kg)
Prep 8M-VACUUMDEGASSER
  • Prep 8M
  • ThePrep 8M vacuum degasser features a single working module with eight degassing ports, enabling the simultaneous preparation of up to eight samples under uniform thermal conditions. All stations operate at the same temperature, making it ideal for processing multiple samples consistently.
  • Designed for efficiency and ease of use, the Prep 8M allows quick disassembly of sample tubes, supports grouped programmed temperature ramping,and features a purge-assisted cooling function for rapid cooldown. Its anti-elutriation design ensures sample integrity throughout the vacuum degassing process.
  • Temperature is fully programmable to deliver consistent and precise thermal treatment, while vacuum and backfill are manually controlled, giving operators the flexibility to manage timing and sequencing based on specific sample requirements
  • Use-Case:
  • Compact benchtop vacuum degasser with semi-automated functionality suited for space-constrained labs needing 8-port capacity.
  • Model Prep 8M
    Temperature RT-400°C

    Control accuracy

    ±1°C
    Degassing port 8
    Pump 1 mechanical pump
    Heating method Programmed
    Dimensions and weight L 15.5 in (395 mm)
    W 18.0 in (455 mm)
    H 14.0 in (358 mm)
    66 lbs (30 kg)

Prep 4M-VACUUM DEGASSER

  • ThePrep 4M vacuum degasser features four independent degassing stations, each with individually adjustable temperature and time parameters. This allows for the simultaneous preparation of multiple samples under different conditions, making it ideal for laboratories handling diverse materials.
  • Designed to maintain sample integrity, the system includes an anti-elutriation design to prevent particle loss during evacuation.It also supports optional programmable temperature ramping for controlled and repeatable heating cycles. Vacuum and nitrogen backfill are manually controlled, giving operators the flexibility to manage process timing based on specific sample requirements.
  • ThePrep 4M offers a compact and versatile solution for reliable sample pretreatment in surface area and gas adsorption analyses.
  • Use-Case:
  • Economical 4-port vacuum degasser for low-to-mid throughput needs; temperature ramping available as an option.
  • Prep 4M
  • Model Prep 4M
    Temperature RT-400°C

    Control accuracy

    ±1°C
    Degassing port 4
    Pump 1 mechanical pump
    (Ultimate vacuum 10-2 Pa, optional)
    Heating method Programmed temperature ramping (Optional)
    Dimensions and weight L 16.0 in (410 mm)
    W 14.5 in (361 mm)
    H 27.6 in (702 mm)
    55 lbs (25 kg)

Prep 8F –FLOW DEGASSER

  • Prep 8F
  • The Prep 8F is a versatile, high-throughput degassing system featuring two independent working units, each with four degassing ports, allowing the simultaneous preparation of up to eight samples. Each unit offers independent control of degassing temperature and time, providing flexibility for handling different sample types.
  • Designed for dynamic(flow) degassing, the system ensures efficient and uniform sample preparation without the use of vacuum. A programmable temperature ramping function enables controlled heating, while a built-in furnace fan facilitates rapid cooling between runs.
  • Operation is streamlined through a 7-inch integrated touchscreen with an intuitive interface and automatic parameter memory, making the Prep 8F an ideal solution for high-throughput sample pretreatment in surface area and gas adsorption analysis
  • Use-Case:
  • Flow-based degasser with 8 ports;designed for applications where vacuum degassing is not preferred or feasible.
  • Model Prep 8F
    Temperature RT-400°C

    Control accuracy

    ±1°C
    Degassing port 8
    Pump 1 mechanical pump
    Heating method Programmed temperature ramping (Optional)
    Dimensions and weight L 27.0 in (680 mm)
    W 16.0 in (404 mm)
    H 15.7 in (400 mm)
    70 lbs (32 kg)