Home
Products
Technical Library
News and Events
About Us
About Us
Career Opportunities
Contact Us
Online Store
Products
Industry
Products
Gas Adsorption
Chemisorption
Reactors
Thermal Analysis
Gravimetric Adsorption
Gas Separation
X-Ray Diffraction
True Density
Accessories
ALL PRODUCTS
Industry
Agriculture
Battery and Electronics
Catalysts
Chemicals
Energetic Materials
Food & Beverage
Metals and Alloy
MOFs
Petroleum
Pharma
Plastic and Polymers
Textiles
NanoMaterials
Sustainable Energy Technologies
Waste Management and Environmental Services
ALL INDUSTRIES
Home
Products
Gas Adsorption
Micro 100
Meso 112/222
Micro 200
Micro 300
Meso 400
AMI-Sync
Surface DX
Vapor 100/200
RuboSORP MPA
Chemisorption
AMI-300
AMI-300SSITKA
AMI-300 IR
AMI-400
AMI-400TPX
Reactors
uBenchCAT
Biofuel BenchCat
Gas Separation
BTsorb 100
Gravimetric Adsorption
RuboSORP MSB
RuboSORP MSB Vapor
Thermal Analysis
DSC
TGA
TMA
STA
X-Ray Diffraction
Lattice GO
Lattice Series
Insight Series
True Density
Densi 100
Accessories
Master 400
Degassers
Switch-6
Technical Library
News and Events
About Us
About Us
Career Opportunities
Contact Us
Online Store
Products
Products
All
Accessories
Chemisorption
Gas Adsorption
Gas Separation
Gravimetric Adsorption
Reactors
Thermal Analysis
True Density
X-Ray Diffraction
Industry
All
Agriculture
Battery and Electronics
Catalysts
Chemicals
Energetic Materials
Food & Beverage
Metals and Alloy
MOFs
Petroleum
Pharma
Plastic and Polymers
Textiles
NanoMaterials
Sustainable Energy Technologies
Waste Management and Environmental Services
Meso 400
High Throughput Mesopore Characterization
Designed for precise specific surface area and mesoporous structure characterization.
Balances high-throughput testing with independent station control.
Available with 4 analysis ports, each with in-situ degassing capability.
Simultaneously analyze different adsorbate gases across up to 4 stations.
Each port features an independent gas inlet.
BET repeatability of ≤ ±1.0% ensures consistent, high-precision results.
Micro 100
High-Resolution Micropore Characterization
Available in multiple models to support diverse lab-throughput needs.
2 analysis stations with high-vacuum pump and up to 3 pressure transducers per station.
Capable of measuring adsorption isotherms down to P/P₀ = 10⁻⁸ for high-resolution micropore characterization.
Simultaneous testing with different adsorbate gases across all active stations.
Integrated design supports up to 2 degassing ports, 2 in-situ, and 1 cold trap within a single cabinet.
BET repeatability of ≤ ±1.0% ensures consistent, high-precision results.
Micro 200
High-Resolution Micropore Characterization
Available in multiple models to support diverse lab-throughput needs.
2 analysis stations with high-vacuum pump and up to 3 pressure sensors per station.
Capable of measuring adsorption isotherms down to P/P₀ = 10⁻⁸ for high-resolution micropore characterization.
Simultaneous testing with different adsorbate gases across all active stations.
Integrated design supports up to 2 degassing ports, 2 in-situ, and 1 cold trap within a single cabinet.
Each analysis port includes a dedicated gas inlet (excluding Micro 100 model).
BET repeatability of ≤ ±1.0% ensures consistent, high-precision results.
Micro 300
High-Resolution Micropore Characterization
Available in multiple models to support diverse lab-throughput needs.
3 analysis stations with high-vacuum pump and up to 3 pressure sensors per station.
Capable of measuring adsorption isotherms down to P/P₀ = 10⁻⁸ for high-resolution micropore characterization.
Simultaneous testing with different adsorbate gases across all active stations.
Equipped with 3 in-situ degassing ports and 1 cold trap.
Each analysis port includes a dedicated gas inlet (excluding Micro 100 model).
BET repeatability of ≤ ±1.0% ensures consistent, high-precision results.
Vapor Series
Volumetric Vapor Adsorption Analyzer
Simultaneously perform vapor adsorption, specific surface area, and pore size distribution measurements.
Independent high-vacuum analysis pathways for vapor, BET surface area, and micropore characterization.
Analyze up to 2 samples at once (1 vapor, 1 micropore) with fully independent stations.
Configurable with 1 or 2 analysis stations to meet varying lab needs.
Includes cold trap, integrated constant-temperature valve box, and illuminated valve status indicators.
Surface DX Series
Cost-Effective Surface Area Analysis for Fast, Reliable Quality Control
Supports Dynamic Flow BET in three modes: patented dynamic reference method, single-point BET, and multi-point BET.
When fully optimized, up to 8 samples can be analyzed per hour across 4 stations.
High-sensitivity thermal conductivity detector with auto-zero for stable, accurate results.
Automatic Dewar elevator and valve status indicator lights streamline operation.
Compact, user-friendly design ideal for routine QC environments.
Widely adopted in carbon materials, battery components, ceramics, metal powders, and other industrial applications.
Densi 100
Fast. Accurate. ISO-Compliant True Density Measurement
Gas displacement method for accurate solid volume and density measurements.
Supports a wide range of sample volumes with interchangeable inserts: 100 / 35 / 10 / 3.5 / 1 ml.
Positive pressure testing—no external vacuum pump needed.
Intuitive touchscreen operation with no external PC required.
Master 400
Quadrupole Mass Spectrometer
Compact, benchtop quadrupole mass spectrometer designed for integration with sorption and reaction systems.
Heated transfer line and ion source prevent condensation of vapor-phase species.
Seamlessly interfaces with AMI breakthrough and chemisorption analyzers to identify desorbed components in gas/vapor streams.
Mass range: 100 amu (Optional upgrades to 200 or 300 amu).
Detection limit: < 500 ppb for high-sensitivity applications.
«
1
2
3